Warning: Undefined variable $DOynAl in /data02/virt118176/domeenid/www.odotautomation.ee/htdocs/wp-includes/default-constants.php on line 1

Warning: Undefined variable $LRLYC in /data02/virt118176/domeenid/www.odotautomation.ee/htdocs/wp-includes/rest-api/endpoints/class-wp-rest-comments-controller.php on line 1

Warning: Undefined variable $GvUDnRZgF in /data02/virt118176/domeenid/www.odotautomation.ee/htdocs/wp-includes/rest-api/endpoints/class-wp-rest-sidebars-controller.php on line 1

Warning: Undefined variable $ABsRtx in /data02/virt118176/domeenid/www.odotautomation.ee/htdocs/wp-includes/widgets/class-wp-widget-custom-html.php on line 1
Products - odotautomation.ee
Products - odotautomation.ee

Products

  • All
  • Analog Input
  • Discrete Input
  • Analog Output
  • Discrete Output
  • Network
CT-4158

459.00

Module features ◆The module supports 8 channels voltage signal output ◆ Output range: 0~5VDC, 0~10VDC, ±5VDC, ±10VDC, 16 bits ◆ The module carries with 8 analog output LED indicators ◆ Module output signal is single – ended common – grounded output

ODOT-S2E2

♦ Supports protocol conversion between Modbus-RTU and Modbus-TCP ♦ Supports the connection of5 TCP clients simultaneously ♦ ODOT-S2E2 supports 2*RS485 ♦ ODOT-S4E2 supports wiring of RS485/RS232/RS422 ♦ Each serial port supports Modbus masterand slave ♦ ODOT-S2E2:2 serial Modbus-RTU/ASCII to Modbus-TCP Server gateway ♦ ODOT-S4E2:4 serial Modbus-RTU/ASCII to Modbus-TCP Server gateway ♦ Supports one key reset ♦ Gateway working mode: Transparent transmission, address mapping

ODOT-DPM01

♦ Supports protocol conversion between Modbus and PROFIBUS ♦ Supports RS485, RS422 and Rs232 ♦ Supports Modbus master and slave, and supports RTU or ASCII ♦ Supports working environment of -40~85°C ♦ PROFIBUS-DP: Max. Input 244 bytes, Max. Output 244 bytes ♦ DPM01:1-way Modbus to PROFIBUS slave gateway, sum of input and output is 288 bytes. ♦ DPM02: (customization) 1-way Modbus-RTU to PROFIBUS slave gateway, sum of input and outputis488 bytes.

MG-CANEX CANopen To Modbus TCP Converter

0.00

MG-CANEX Protocol Converter CANopen to Modbus TCP protocol converter MG-CANEX is a protocol converter from CANopen to Modbus TCP. The device plays as the master in the CANopen network and it could be connected to the standard CANopen slave devices. The data transmission supports PDO, SDO, and error control supports Heartbeat. It Supports synchronous and asynchronous message sending. As a TCP server in Modbus TCP network, the device could be accessed by 5 TCP clients at the same time, and it could be connected to PLC controller and various kinds of configuration software. It could also connect optical transceiver and…

ODOT-S1E1 V2.0

This is a converter developed by Sichuan Odot Automation System Co., LTD between RS232/485/422 and TCP/UDP.This protocol converter can easily connect serial port devices to Ethernet and realize network upgrade of serial port devices. Protocol converter supports the function of “data transmission”, which can be set as a client or a server. This function can easily realize the data communication between PLC, server and other Ethernet devices and the underlying serial port devices. Supports TCP server and TCP client transparent transmission Supports UDP transparent transmission and virtual serial ports Supports transparent transmission with or without protocol. Protocol transparent transmission supports MODBUS RTU/ASCII Supports…

Load More

End of Content.

Email: info@vlantex.com
Tel: +372 5234 991
Address: Sinilille street 6/1 office 9
Scroll to Top