Special Module - odotautomation.ee
Special Module - odotautomation.ee

Special Module

  • Special Module
CT-5102

◆ The module supports two channels of encoder input. ◆ Each encoder channel supports A/B incremental encoder or pulse-directional encoder input. ◆ Each encoder channel supports orthogonal A/B signal input, input voltage 5V, and it supports source and sink input. ◆ The incremental encoder mode supports x1/ x2 / x4 frequency multiplication to be selectable. ◆ The pulse – direction mode supports nondirectional signal, pulse input only. ◆ Each encoder channel supports 1 digital input signal with an input voltage of 5Vdc or 24Vdc. ◆ Each encoder channel supports 1 digital output signal with an output voltage of 5Vdc. ◆…

CT-5122

◆ The module supports two channels of SSI encoder input. ◆ Each encoder channel supports SSI absolute encoder signal input. ◆ Each encoder channel supports 1 digital input signal with an input voltage of 5Vdc or 24Vdc. ◆ Each encoder channel supports 1 digital output signal with an output voltage of 5Vdc. ◆ The module internal bus and field input adopt magnetic isolation ◆ The module carries 16 LED indicators. ◆ The module supports the maximum clock frequency of 2MHz. ◆ The encoder reading interval time could be set. ◆ The data bit length and the start and end bit…

CT-5142

◆ The module supports two channels of encoder input. ◆ Each encoder channel supports A/B incremental encoder or pulse-directional encoder input.| ◆ Each encoder channel supports orthogonal A/B differential signal input, voltage output range 0-5V. ◆ The incremental encoder mode supports x1/ x2 / x4 frequency multiplication mode. ◆ The pulse – direction mode supports nondirectional signal, pulse input only. ◆ Each encoder channel supports 1 digital input signal with an input voltage of 5Vdc or 24Vdc. ◆ Each encoder channel supports 1 digital output signal with an output voltage of 5Vdc. ◆ The module internal bus and field input…

CT-623F

109.00

CT-623F: 8-channel digital input /24VDC/ source or sink type & 8-channel digital output /24VDC/ source type Module features ◆ The module supports 8-channel digital input, and supports source type and sink type two-way input. The input voltage is 0V/24VDC. ◆ The module supports 8-channel digital output, Output high level valid, and the output voltage is 24VDC. ◆ Module input channel can collect digital output signal of field equipment. (dry contact or active output) ◆ The module input channel can be connected to the 2-wire or 3-wire digital sensor

CT-5321

239.00

CT-5321 Modbus Serial Port Module 1 Module Description The Modbus serial port module supports 1 channel RS485/RS232 /RS422(optional), supports Modbus RTU/ASCII protocol, and supports master, slave and free transparent transmission mode. The serial Module CT-5321 could be applied with the adapter modules, so it could convert Modbus into other protocols such as Modbus TCP, Profinet, EtherCAT, EtherNet/IP, etc. When the module is used, serial port parameters and Modbus instructions should be configured in IO Config software. Devices with RS485/RS232/RS422 interface, which support modbus-RTU/ASCII, could be applied with CT-5321 to realize interconnection with upper PLC or upper computers. CT-5321 could be…

CT-5721

126.00

CT-5721 Bus extended slave module The bus extened slave module is used to extend the bus.The bus extended slave module has no process data and configuration parameters.

CT-5801

CT-5801: Terminal module Terminal modules are used to stabilize the internal bus communication. Each C series I/O protocol adapter must be equipped with 1pc of terminal module CT-5801 no matter how many sub-modules are connected. The dustproof terminal could cover the internal bus and field power supply hardware of the last IO module. And terminal modules have no process data and configuration parameters. * Take no module channel and replace CT-5800.

CT-5112

◆ the module supports two channels of encoder input. ◆ each encoder channel supports A/B incremental encoder or pulse-directional encoder input. ◆ each encoder channel supports orthogonal A/B signal input, input voltage 24V, and it supports source and sink input. ◆ the incremental encoder mode supports x1/ x2 / x4 frequency multiplication mode. ◆ the pulse – direction mode supports nondirectional signal, pulse input only. ◆ each encoder channel supports 1 digital input signal with an input voltage of 5Vdc or 24Vdc. ◆ each encoder channel supports 1 digital output signal with an output voltage of 24Vdc. ◆ each encoder…

CT-5711

92.00

CT-5711 Bus extended master module Module Description The bus extened master module is used to extend the bus.The bus extended master module has no process data and configuration parameters.